Product Details
The Direxion Microcatheter is available in six tip configurations, as shown below. The distal tip is available in four pre-shaped options: Straight, Bern Shape, J Shape, and Swan Shape. These shapes are designed to facilitate access to the most challenging anatomy. Direxion Microcatheters are also available with two radiopaque markers, 2RO, which is designed to aid in the delivery of detachable embolic coils during embolization procedures.
|
Direxion Microcatheter |
Direxion HI-FLO Microcatheter |
---|---|---|
Lumen Size (in) |
0.021” |
0.027” |
Distal Tip Size (F) |
2.4F |
2.8F |
Length Options |
105, 130, 155 cm |
|
Number of UPNs |
14 |
12 |
Tip Shapes |
Straight, Bern, J, Swan |
|
2 RO Marker Options |
Straight and Bern |
N/A |
Pre-loaded System Offering |
Fathom™-16 Guidewire Transend™-14 Guidewire |
Fathom-16 Guidewire Transend-18 Guidewire |
Maximum Injection Pressure |
1200 PSI |
|
Maximum Flow Rate @ 1200 PSI |
3.5 mL/s |
6.3 mL/s |
Hydrophilic Coating |
Yes |
Yes |
|
Direxion Microcatheter |
Direxion HI-FLO Microcatheter |
---|---|---|
Guidewire Size |
≤ 0.018” |
≤ 0.021” |
Max Diagnostic Catheter Size |
0.035” |
0.038” |
Compatible with 0.018” coils |
Yes |
No |
Non-Spherical Embolic Particles |
Up to ≤ 500 Micron |
Up to ≤ 700 Micron |
Spherical Embolic Particles |
Up to ≤ 710 Micron |
Up to ≤ 900 Micron |
Compatible with Chemical Agents (Glue, DMSO, Alcohol, Chemotherapy) |
Yes |
Yes |
Direxion Torqueable Microcatheters |
||||||||
UPN / Order Code |
Catalog No. |
GTIN |
Usable Length |
Proximal/ |
Lumen |
Tip Shape |
RO Markers |
C-Code |
---|---|---|---|---|---|---|---|---|
M001195200 |
19-520 |
08714729839316 |
105 |
2.7/2.4 |
0.021 |
Straight |
1 |
C1887 |
M001195210 |
19-521 |
08714729839323 |
130 |
2.7/2.4 |
0.021 |
Straight |
1 |
C1887 |
M001195220 |
19-522 |
08714729839330 |
155 |
2.7/2.4 |
0.021 |
Straight |
1 |
C1887 |
M001195230 |
19-523 |
08714729839347 |
105 |
2.7/2.4 |
0.021 |
Bern |
1 |
C1887 |
M001195240 |
19-524 |
08714729839354 |
130 |
2.7/2.4 |
0.021 |
Bern |
1 |
C1887 |
M001195250 |
19-525 |
08714729839361 |
155 |
2.7/2.4 |
0.021 |
Bern |
1 |
C1887 |
M001195260 | 19-526 | 08714729839378 | 105 | 2.7/2.4 | 0.021 | J | 1 | C1887 |
M001195270 |
19-527 |
08714729839385 |
130 |
2.7/2.4 |
0.021 |
J |
1 |
C1887 |
M001195280 | 19-528 | 08714729839392 | 155 | 2.7/2.4 | 0.021 | J | 1 | C1887 |
M001195290 | 19-529 | 08714729839408 | 105 | 2.7/2.4 | 0.021 | Swan | 1 | C1887 |
M001195300 |
19-530 |
08714729839415 |
130 |
2.7/2.4 |
0.021 |
Swan |
1 |
C1887 |
M001195310 | 19-531 | 08714729839422 | 155 | 2.7/2.4 | 0.021 | Swan | 1 | C1887 |
M001195320 |
19-532 |
08714729839439 |
130 |
2.7/2.4 |
0.021 |
Straight |
2 |
C1887 |
M001195330 | 19-533 | 08714729839446 | 155 | 2.7/2.4 | 0.021 | Straight | 2 | C1887 |
M001195340 |
19-534 |
08714729839453 |
130 |
2.7/2.4 |
0.021 |
Bern |
2 |
C1887 |
M001195350 | 19-535 | 08714729839460 | 155 | 2.7/2.4 | 0.021 | Bern | 2 | C1887 |
Direxion HI-FLO Torqueable Microcatheters |
||||||||
UPN / Order Code |
Catalog No. |
GTIN |
Usable |
Proximal/ |
Lumen |
Tip Shape |
|
C-Code |
---|---|---|---|---|---|---|---|---|
M001195400 |
19-540 |
08714729839477 |
105 |
3.0/2.8 |
0.027 |
Straight |
|
C1887 |
M001195410 |
19-541 |
08714729839484 |
130 |
3.0/2.8 |
0.027 |
Straight |
|
C1887 |
M001195420 |
19-542 |
08714729839491 |
155 |
3.0/2.8 |
0.027 |
Straight |
|
C1887 |
M001195430 |
19-543 |
08714729839507 |
105 |
3.0/2.8 |
0.027 |
Bern |
|
C1887 |
M001195440 |
19-544 |
08714729839514 |
130 |
3.0/2.8 |
0.027 |
Bern |
|
C1887 |
M001195450 |
19-545 |
08714729839521 |
155 |
3.0/2.8 |
0.027 |
Bern |
|
C1887 |
M001195470 |
19-547 |
08714729839545 |
130 |
3.0/2.8 |
0.027 |
J |
|
C1887 |
M001195480 | 19-548 | 08714729839552 | 155 | 3.0/2.8 | 0.027 | J | C1887 | |
M001195500 |
19-550 |
08714729839576 |
130 |
3.0/2.8 |
0.027 |
Swan |
|
C1887 |
M001195510 | 19-551 | 08714729839583 | 155 | 3.0/2.8 | 0.027 | Swan | C1887 |
Direxion Fathom - 16 System Pre-Loaded Torqueable Microcatheters |
||||||||
UPN / Order Code |
Catalog No. |
GTIN |
Usable |
Proximal/ |
Lumen |
Tip Shape |
Fathom 16 Steerable Guidewire Overall Length |
C-Code |
---|---|---|---|---|---|---|---|---|
M001195610 |
19-561 |
08714729839606 |
130 |
2.7/2.4 |
0.021 |
Straight |
180 |
C1887 |
M001195620 | 19-562 | 08714729839613 | 155 | 2.7/2.4 | 0.021 | Straight | 180 | C1887 |
M001195640 |
19-564 |
08714729839637 |
130 |
2.7/2.4 |
0.021 |
Bern |
180 |
C1887 |
M001195650 | 19-565 | 08714729839644 | 155 | 2.7/2.4 | 0.021 | Bern | 180 | C1887 |
M001195660 | 19-566 | 08714729839651 | 130 | 2.7/2.4 | 0.021 | Straight | 180 | C1887 |
M001195670 | 19-567 | 08714729839668 | 130 | 2.7/2.4 | 0.021 | Bern | 180 | C1887 |
Direxion Transend - 14 System Pre-Loaded Torqueable Microcatheters |
||||||||
UPN / Order Code |
Catalog No. |
GTIN |
Usable |
Proximal/ |
Lumen |
Tip Shape |
Fathom 16 Steerable Guidewire Overall Length |
C-Code |
---|---|---|---|---|---|---|---|---|
M001195810 |
19-581 |
08714729839743 |
130 |
2.7/2.4 |
0.021 |
Straight |
165 |
C1887 |
M001195840 |
19-584 |
08714729839774 |
130 |
2.7/2.4 |
0.021 |
Bern |
165 |
C1887 |
M001195850 | 19-585 | 08714729839781 | 155 | 2.7/2.4 | 0.021 | Bern | 165 | C1887 |
Direxion HI-FLO Fathom - 16 System Pre-Loaded Torqueable Microcatheters |
||||||||
UPN / Order Code |
Catalog No. |
GTIN |
Usable Length |
Proximal/ |
Lumen |
Tip Shape |
Fathom 16 Steerable Guidewire Overall Length |
C-Code |
---|---|---|---|---|---|---|---|---|
M001195710 |
19-571 |
08714729839682 |
130 |
3.0/2.8 |
0.027 |
Straight |
180 |
C1887 |
M001195720 | 19-572 | 08714729839699 | 155 | 3.0/2.8 | 0.027 | Straight | 180 | C1887 |
M001195740 |
19-574 |
08714729839712 |
130 |
3.0/2.8 |
0.027 |
Bern |
180 |
C1887 |
M001195750 | 19-575 | 08714729839729 | 155 | 3.0/2.8 | 0.027 | Bern | 180 | C1887 |
Direxion HI-FLO Transend - 18 System Pre-Loaded Torqueable Microcatheters |
||||||||
UPN / Order Code |
Catalog No. |
GTIN |
Usable Length |
Proximal/ |
Lumen |
Tip Shape |
Fathom 16 Steerable Guidewire Overall Length |
C-Code |
---|---|---|---|---|---|---|---|---|
M001195910 |
19-591 |
08714729839828 |
130 |
3.0/2.8 |
0.027 |
Straight |
165 |
C1887 |
M001195940 |
19-594 |
08714729839842 |
130 |
3.0/2.8 |
0.027 |
Bern |
165 |
C1887 |
The C-Code used for the Direxion Torqueable Microcatheter is C1887. C-Codes are used for hospital outpatient device reporting for Medicare and some private payers. Note: Boston Scientific Corporation is not responsible for correct use of codes on submitted claims; this information does not constitute reimbursement or legal advice.
Product Code | - |
Application | HI-FLO Torqueable Microcatheters |
Manufacturer Country | USA |
Guarantee Type | Based on manufacturer recommendations |